C-21 VOC Gas Sensor

Simple, Inexpensive VOC Gas Sensor
Includes Audio Alarm, Battery operation and Provision for External Alarm and Data Logger
VOC Gas Sensor C-21 For paint shops, printers, dry cleaners, woodworkers, vehicle repair facilities, chemical production areas and wherever indoor air quality monitoring is required: the Eco Sensors® Model C-21 gas sensor helps you comply with the new VOC air quality regulations for hydrocarbon gases and solvent vapors.

Benefits:

  • Constantly monitors your work environment. Detects leaks and poor air quality before they are a health hazard. Alarms below OSHA TLV for most common solvent-based VOCs.
  • No installation. Easily used and understood by non-technical personnel.
  • Virtually no maintenance.

Features:

  • Highly sensitive to solvent vapors and other VOCs. Bright green-yellow-red display clearly shows hazard level of gas or vapor.
  • Detects down to OSHA, EPA, and other regulatory-mandated levels...typically at low ppm concentrations.
  • Has built-in rechargeable battery for portable use in tracking leaks.
  • Rugged construction with many safety features.

Specifications:

  • Range: Full scale = 50-100 ppm for most solvent based VOCs.
  • Bargraph display: Green = normal. Yellow = caution. Red = danger.
  • Response time: Within a few seconds of the VOC gas reaching the sensor.
  • Measurement principle: HMOS (heated metal oxide semiconductor) sensor.
  • Size: 85 × 35 × 60 mm (3.25 × 1.375 × 2.375 in)
  • Weight: 140 gr (5 oz).
  • Power requirements: 12 VDC at 300 mA. AC adapters available worldwide.
  • Battery: Self-contained NiCad or NiMH. Approximately 2 hour capacity. Recharged by AC adapter overnight.