OS-4 Ozone Controller and Monitor
Acts like a thermostat to control ozone generators and alarms based on adjustable ozone concentration set-points. Ozone ppm readout via digital meter. Simple and effective. Ships with SM-500 / RME-O3-20, 0-20 ppm sensor module.
- SM-500/RME 0-20 ppm: ACTIVE – IN STOCK:
- Smaller form-factor electrochemical-based sensor module with re-zero button, T/RH compensation, and reduced VOC sensitivity. Available for OS-4 with a calibration range of 0-20 ppm – MORE INFO
- SM-7/SM-EC 0-20 ppm: END OF LIFE – NO STOCK REMAINING
Features:
- Easy to install. Minimal adjustments.
- Sensor is in a replaceable precalibrated module. Separated by a cable, the instrument is not in the high ozone area.
- Sensor reading is temperature and relative humidity compensated.
- Replacement sensor is miniature, low cost, and pre-calibrated.
- Operates from 12-24 VDC or from AC adapters available worldwide.
- Alarms, data loggers, and other accessories available.
- Programmable turn-on and turn-off set-points.
- Indication when .1 ppm safety standard exceeded.
Typical Applications:
- Monitor ozone levels in treatment storage areas for fruits, vegetables, and other agricultural products. Monitor ozonated HVAC systems. General monitoring at 0.03-20 ppm.
- Control the output of ozone generators using the set-point controlled relay in the OS-4.
- Use as either ozone leak alarm or ozone failure alarm for all sizes of ozone generators.
Specifications:
- Range and Accuracy: 0.03-20 ppm of ozone.
- Accuracy: 10-15% (Depends on application).
- Temperature and humidity: 5-40°C, 20-95% RH
- Measurement Principle: SPEC (Screen Printed Electrochemical) sensor.
- Size: 127 × 64 × 42 mm (5 × 2.5 × 1.625 in).
- Weight: 200 g (7 oz)
- Power Requirements: 12-24 VDC, 300 mA. AC adapters available.
- Output control: SPDT non-latching relay. Contacts rated at 5 amps, 250 VAC.
- .1 ppm danger alarm: Panel LED and SPDT relay 5 amp contacts.
- Connections: Terminal blocks for relay output and DC input. 2.5 mm DC power jack for AC adapter.
- Indicators: Green LED: instrument on. Yellow LED: > 0.1 ppm. Red LED: generator on.
- Outputs: 0-2 V, 4-20mA, RS-232 digital.
- Case: Flame-resistant ABS with mounting ears.
- Not recommended for use in the presence of strong acid gases or VOC fumes.
Product manual PDF file (186kb) (requires Adobe Acrobat ™ reader)
Instructions for viewing and capturing data output: RS-232 Communications Manual